NPPF leaves SuDS challenges unresolved

The new NPPF introduces a welcome focus on drainage, SuDS and flood risk management. But there are still some unanswered questions, particularly around water quality and climate change resilience, says Stuart Crisp, UK Manager, Advanced Drainage Systems.

On August 17th 2026, the Ministry for Housing, Communities and Local Government (MHCLG) published the revised National Planning Policy Framework (NPPF). The new framework brought in significant changes for sustainable drainage systems (SuDS), effectively requiring all new developments of any size to demonstrate that they have been designed to the National Standards for Sustainable Drainage Systems.

Policy F8 in the NPPF, which sits in chapter 18 ‘Managing flood risk and coastal change’, covers sustainable drainage systems and watercourses. As well as saying that any development that impacts on drainage on or around the site should incorporate SuDS, F8 says that the SuDS should have maintenance arrangements in place to ensure acceptable operation over their lifetime. And that proposals for major developments should take account of advice from the Lead Local Flood Authority.

The changes brought in under NPPF links to the non-statutory National Standards for SuDS, which was published in June 2025 and updated in July 2026, and aims to move us forward to the more widespread use of SuDS in England. However, the planning guidance places a heavy weighting on flood risk management, rather than water runoff management, leaving more nuanced questions unanswered around how to protect water quality and how to ensure climate change resilience.

We have been expecting the deployment of SuDS for new developments to become mandatory since the Flood and Water Management Act 2010 (FWA) came into play. However, Schedule 3 of that act which would remove the automatic right to connect surface water to public sewers, requiring SuDS Approving Bodies (SABs) to approve drainage systems, has still not been enacted in England.

The introduction of the new NPPF means that while a formal statement on SuDS arrangements for a proposed scheme must be part of most planning applications, no statutory approval process is in place. Clause F8 of the NPPF, regarding SuDS, uses the language of ‘should’, which implies that this is a recommendation or an optional voluntary undertaking, rather than the stronger ‘shall’ which sets a requirement.

Also, by driving SuDS implementation through the planning process, it implies that planners should have the requisite knowledge and skills to appropriately interpret design proposals from developers and to scrutinise recommendations from LLFAs. Without such attributes, avoidable, sub-optimal solutions may become adopted.

It is worth noting here that different regulations apply in other parts of the UK. In Wales, Schedule 3 of the FWA was enacted in 2019, which means that SuDS proposals are assessed by people with specialist SuDS knowledge sitting on SABs. SuDS are also mandatory for new developments in Scotland. SuDS approval in Northern Ireland is evolving, moving towards formal regulation with new legislation in the Water, Sustainable Drainage and Flood Management Bill. The current process involves a planning application following specific council guidelines.

How long is a lifetime?
Clause F8(2)(b) of the NPPF says that SuDS should ‘have maintenance arrangements in place to ensure an acceptable standard of operation for the anticipated lifetime of the development’. For housing developments, the design life would generally be 50 years, but the lifetime of the assets on the development are expected to be significantly longer than 50 years. It is the extended life of the asset, not the design life, which should be interpreted against the “lifetime of the development” requirement.

For example, adoptable sewers and infrastructure are generally designed for between 50 and 120 years, depending on the standard specifications of the water company involved.

Chapter 7 of the National Standards for SuDS, which deals with design, operation and maintenance, sheds more light on the subject. It includes sections on ensuring the structural integrity of SuDS and the requirement for a maintenance and management plan including inspection, maintenance and replacement regimes related to both hydraulic performance and pollution control.

When it comes to designing for operation and maintenance, it is pollution control which is often overlooked or only partially understood. The build-up of sediment, whether in a proprietary component or in a green one such as the inlet to a pond, is often considered with respect to hydraulic performance.

Designers and asset owners should also consider harmful pollutants contained in sediment, how this affects green infrastructure, and how it accumulates over time, potentially harming plant and aquatic life.

While SuDS, wherever possible, should be designed to mimic nature, using green measures such as detention basins, ponds and swales, there are situations where proprietary below ground products used alongside them would be beneficial. For instance, where pollution loads are likely to be higher, proprietary solutions can remove pollutants before surface water reaches a pond or flows into a water body and affects aquatic life and the surrounding environment. This approach can provide protection to the green SuDS infrastructure from toxic substances contained in the runoff, either from a single rainfall event or accumulated over time. It can also offer a more efficient and cost-effective alternative to removing sediment from a pond or other green SuDS component.

Although water quality receives a scant mention in relation to SuDS in the NPPF, Standard 4 of the National Standards for SuDS (clause 4.7) recognises that proprietary components may be needed to remove pollutants. It says that land uses with a higher risk of pollution ‘are likely to require proprietary treatment products as part of the management train to ensure adequate treatment.’ This clause also calls for sufficient evidence to prove that they will ‘provide the necessary treatment for the lifetime of the development with appropriate maintenance.’

This brings us onto the thorny question of adoption. Standard 7 says that SuDS that don’t lie within the boundaries of a property owner should be adopted by ‘an appropriate body’. The mechanism of commuted sums is deployed, where the adopting body (asset owner) is provided with a monetary sum from the developer for the ongoing upkeep of the SuDS system over the agreed “lifetime.” It is essential that the commuted sum is an accurate estimate of the costs. If the planner has insufficient knowledge and experience to make a judgement, this estimate may be wildly at odds with the actual costs. Currently, in England, the appropriate body could be the developer or owner of the site, a third-party maintenance company or it could be a water company. Only the enactment of Schedule 3 of the FWA would mandate adoption. Under Schedule 3, the adopting body is the local authority at County or Unitary Authority level.

This issue should be of particular importance to developers and their designers. For green SuDS, planting design, its resilience to climate change and the impact of pollutants over time should all be factored in. And for proprietary below-ground SuDS components, developers and adopters should assure themselves that the structural performance, integrity and pollution control performance of products is as claimed and that they have been independently verified in line with the appropriate standards.

Multi-faceted resilience
The need to build in resilience to climate change receives plenty of mentions in both the NPPF and the National Standards for SuDS. However, the means for doing this are broad brush and are largely focussed on water quantity – reducing the risk of flooding – with some mentions, such as trees in new developments (N3), relating to biodiversity and amenity.

The National Standards for SuDS do provide means of allowing for climate change in hydraulic design. But there again, these are rather blunt instruments, involving the upsizing of infrastructure by a certain percentage.

Standard 3 says that the most up-to-date climate change allowance – as defined by the Environment Agency – shall be used, and that it should be an Upper End Allowance in relation to the lifetime of the development (clause 3.8); and it says that an urban creep uplift factor of 10% should be applied to all developments, apart from those such as flats with no external private permeable spaces (clause 3.33).

When it comes to water quality, more work is needed to understand the impacts of climate change.

Whilst climate change impacts are considered in the hydraulic design of SuDS to increase flows and volumes, no such adaptations are made in relation to water quality. Prolonged dry periods can lead to increased contaminant deposition on catchment surfaces and the need to treat higher pollution loads. In the absence of guidance, an experienced engineer should use judgement on the appropriateness of the SuDS water quality management train to deal with climate change.

It should also be understood that the hydraulic design values used for sizing of flows and volumes are not the same as treatment flow rates for water quality. Water quality SuDS components should be able to deliver the required water quality values at the defined treatment flow rates and provide a means to bypass flows exceeding the treatment flow rate.

For vegetative SuDS, CIRIA 753 The SuDS Manual provides mitigation indices (MIs) using a Simple Index Approach, which evaluates how well different forms of green SuDS deal with different pollutant types, which can then be used to select the appropriate combination of natural components in a SuDS management train. However, the MIs are static numbers and therefore do not consider the impacts of climate changes such as baked or frozen ground during rainfall events or the long-term effects of accumulated contamination from polluted runoff.

With proprietary manufactured components, MIs do not vary as they have been determined under controlled conditions based on recognised industry test methodologies. British Water’s 2022 How To Guide, Applying The CIRIA SuDS Manual (C753) Simple Index Approach To Proprietary/Manufactured Stormwater Treatment Devices, provides a method for calculating MIs. Designers can then use these figures, having assured themselves that they have been independently verified, to select a reliable combination of components to treat likely surface water pollution within a development area.

Water tables can also rise when there is exceptionally high rainfall. The Environment Agency says that this is most likely in areas where the underlying bedrock is chalk and can also occur in areas where the ground is made up of sands and gravels.

Groundwater rebound can impact negatively on SuDS such as infiltration devices and soakaways because the soil beneath them can become saturated and therefore less able to soak up water. It can also adversely affect below ground attenuation components, reducing the infiltration capacity or causing uplift due to buoyancy, which in turn can cause structural damage.

A lack of expertise?
Although we still have a way to go with respect to some of the more complex issues relating to SuDS standards and designs, the new NPPF should mean that SuDS are considered at the earliest stages of a development’s design, rather than shoehorned in after site layouts have been set. This applies to any proposal that could affect drainage, so experts are advising that any planning application should include a statement showing how the design of the development conforms to the National Standards for SuDS, in proportion to the scale of the development.

The requirement for a SuDS statement clearly places a greater burden on local planning authorities and a need for in-house knowledge on SuDS. Even for major developments, where the NPPF calls for the Lead Local Flood Authority to be involved in an advisory capacity, the spotlight is again on flooding, sidelining the other aspects of SuDS.

Some councils have already made the point that planning officers do not have the expertise to assess the likely effectiveness of proposed SuDS measures. This suggests that local planning authorities will have to employ specialist drainage experts.
What this will mean in practice is that different local authorities will provide varying levels of commitment, and competence, when it comes to the provision of SuDS.

Adding this factor into the gaps and challenges already addressed in this article, the inclusion of SuDS in the NPPF may still not be a strong enough measure to embed effective, resilient SuDS into our future developments.